{"id":4870,"date":"2020-12-04T18:04:02","date_gmt":"2020-12-04T17:04:02","guid":{"rendered":"https:\/\/www.mdresistor.com\/monitoring-control-system\/"},"modified":"2022-02-02T02:21:54","modified_gmt":"2022-02-02T01:21:54","slug":"supervision-and-steering","status":"publish","type":"page","link":"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/","title":{"rendered":"3.3.1 Supervision and management"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h1>Load bank : piloting and innovative &#8220;BASIC&#8221; and &#8220;PREMIUM&#8221; control systems<\/h1>\n<\/div><div ><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" style=\"--button_margin-top:5%;\" target=\"_self\" href=\"https:\/\/www.mdresistor.com\/en\/contact\/\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">RECEIVE A PERSONALIZED QUOTE WITHIN 24H<\/span><\/a><\/div>\n<\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"800\" height=\"483\" alt=\"User login configuration\" title=\"Config_LoginUser-min\" src=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Config_LoginUser-min.png\" class=\"img-responsive wp-image-4515\" srcset=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Config_LoginUser-min-200x121.png 200w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Config_LoginUser-min-400x242.png 400w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Config_LoginUser-min-600x362.png 600w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Config_LoginUser-min.png 800w\" sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 600px\" \/><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" id=\"un\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-2\" style=\"--awb-content-alignment:left;\"><p>METAL DEPLOYE RESISTOR is developing several innovations in terms of ergonomics, system performance and control methods:<\/p>\n<ul>\n<li>Control via touch screen locally or remotely (or Modbus)<\/li>\n<li>Manual or automatic control<\/li>\n<li>In combination with basic or advanced features<\/li>\n<\/ul>\n<p>At design stage, our load banks are fitted with a <strong>piloting system<\/strong> .<\/p>\n<p><strong>According to your functional needs, two control modes<\/strong> are offered:<\/p>\n<ul>\n<li>Supervision in \u201cBASIC\u201d mode<\/li>\n<li>Supervision in \u201cPREMIUM\u201d mode<\/li>\n<\/ul>\n<p><strong>Depending on your mode of use, several control systems<\/strong> can be recommended:<\/p>\n<ul>\n<li>One control by illuminated button<\/li>\n<li>An external command for control from another system<\/li>\n<li>A Ballasting \/ deballasting control mode<\/li>\n<li>The Master Supervision<\/li>\n<\/ul>\n<\/div><div class=\"fusion-text fusion-text-3\" style=\"--awb-content-alignment:left;\"><p>The automation controls and commands all of the load bank control functions (excluding the generator set).<\/p>\n<p>Supervision is available<strong> in French and English<\/strong> . It can be personalized by the customer.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-gris\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-4\" style=\"--awb-content-alignment:center;\"><h2>Charging power control by touch screen<\/h2>\n<\/div><div class=\"fusion-text fusion-text-5\" style=\"--awb-content-alignment:left;\"><p>All our load banks are fitted with a<strong> PLC controlled by an HMI (Human Machine Interface)<\/strong> with color display.<\/p>\n<p>It allows to :<\/p>\n<ul>\n<li>control load impact<\/li>\n<li>increase or decrease the power progressively, from zero to the nominal power of the load bank<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-blanc\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-6\" style=\"--awb-content-alignment:center;\"><h2>\u201cBASIC\u201d supervision: manual control, basic functions<\/h2>\n<\/div><div class=\"fusion-text fusion-text-7\" style=\"--awb-content-alignment:left;\"><p>This mode allows you to control the load bank directly and manually. All the essential functions to control your load bank are available:<\/p>\n<ul>\n<li>touch screen control,<\/li>\n<li>visualization of faults,<\/li>\n<li>voltage presence indication &#8230;<\/li>\n<\/ul>\n<p>Load control is carried out from a<strong> 4.3 inch touch screen<\/strong> .<\/p>\n<h3>Manual control: handling of loads at the initiative of the operator<\/h3>\n<p>The power selection varies from 0 to the nominal power of the load bank. The resolution is given by the smallest power notch.<br \/>\nThe selected loads are energized by three-phase contactors.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"369\" height=\"265\" title=\"supervision banc de charge MDR 2-min\" src=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/supervision-banc-de-charge-MDR-2-min.png\" alt class=\"img-responsive wp-image-4465\" srcset=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/supervision-banc-de-charge-MDR-2-min-200x144.png 200w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/supervision-banc-de-charge-MDR-2-min.png 369w\" sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 369px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-8\"><p><strong>Input value<\/strong> : power (in kW), a &#8220;Validation&#8221; button activates the corresponding loads.<br \/>\nIf this value is within the possibilities of the load bank, the load engaged will be equal to the setpoint. Otherwise, the load bank will provide the lower load within its possibilities.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-9\"><p><span style=\"font-weight: 400;\">A visual alert on the touch screen warns us when a fault is detected.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A window allows you to see the state of the load bank and allows you to acknowledge any faults.<\/span><\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-gris\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-10\" style=\"--awb-content-alignment:center;\"><h2>\u201cPREMIUM\u201d supervision: automatic control, advanced functions<\/h2>\n<\/div><div class=\"fusion-text fusion-text-11\" style=\"--awb-content-alignment:left;\"><p>This mode, in addition to the functions of the \u201cBASIC\u201d Supervision version, allows:<\/p>\n<ul>\n<li><strong>additional features<\/strong><\/li>\n<li><strong>coupling to an automatic Ballasting \/ Shedding function<\/strong> (\u201cBallast\u201d operation). Using a measuring unit, the load bank will detect when the generator set is operating under regime (according to customer data and the information set in the PLC). Thus, it will fill the lack of load to allow the engine to run at a rated power level.<\/li>\n<\/ul>\n<p>Load control is carried out from a<strong> 7 inch touch screen<\/strong> .<\/p>\n<p>The piloting is carried out either directly by an operator in manual mode, or in automatic mode according to pre-recorded recipes.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"800\" height=\"482\" alt=\"Editor cycle\" title=\"Cycle_Editeur-min\" src=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Cycle_Editeur-min.png\" class=\"img-responsive wp-image-4516\" srcset=\"https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Cycle_Editeur-min-200x121.png 200w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Cycle_Editeur-min-400x241.png 400w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Cycle_Editeur-min-600x362.png 600w, https:\/\/www.mdresistor.com\/wp-content\/uploads\/2020\/12\/Cycle_Editeur-min.png 800w\" sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 600px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-12\" style=\"--awb-content-alignment:left;\"><h3>Configuration of charge cycles: recording of recipes<\/h3>\n<p>A recipe can be used for any test:<\/p>\n<ul>\n<li>Input value: power (kW), time (s)<\/li>\n<li>Storage of 20 cycles of 20 steps with possible looping<\/li>\n<li>Possibility of requesting validation before moving to the next step<\/li>\n<\/ul>\n<p>The \u201cPREMIUM\u201d function offers the possibility of having a<a href=\"https:\/\/www.mdresistor.com\/en\/programmable-load-bank\/\"> programmable load bank with automatic test cycles<\/a> .<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-13\" style=\"--awb-content-alignment:left;\"><h3>Automatic mode: allows you to launch a pre-recorded recipe<\/h3>\n<p>Instant reading of the various electrical values of the load bank during the tests.<\/p>\n<ul>\n<li>Phase currents<\/li>\n<li>Simple and compound voltages<\/li>\n<li>Frequency<\/li>\n<li>Active, reactive and apparent power<\/li>\n<li>The power factor<\/li>\n<\/ul>\n<p>These values are available in live visualization and on curves.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-14\"><h3>Monitoring of the current test - Test values - Curves<\/h3>\n<\/div><div class=\"fusion-text fusion-text-15\" style=\"--awb-content-alignment:left;\"><h3>Storage of cycle values in CSV format<\/h3>\n<p>All the measured values are recorded, retrievable by a USB plug and manageable in EXCEL.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-16\" style=\"--awb-content-alignment:left;\"><h3>Option: Remote control system<\/h3>\n<h4>A console equipped with a 7-inch touch screen and an emergency stop is used to control the load bank.<\/h4>\n<h4>Two cable lengths of 10m or 20m.<\/h4>\n<h4>The connection is made by plug.<\/h4>\n<h4>A compartment in the load bank is used to store this console and its cable<\/h4>\n<p>Operation, 2 choices:<\/p>\n<ul>\n<li>The remote control replaces the fixed touch screen on the load bank. It will be the only means of control.<\/li>\n<li>The local control and the remote control can control the load bank.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-6 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-blanc\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-17\" style=\"--awb-content-alignment:center;\"><h2>Control systems: local, manual or external control<\/h2>\n<\/div><div class=\"fusion-text fusion-text-18\" style=\"--awb-content-alignment:left;\"><p>The METAL DEPLOYE RESISTOR range of load banks can be controlled via different control systems.<\/p>\n<h3>Local order<\/h3>\n<p>The touch screen is integrated into the load bank. In other words, an autonomous control panel is integrated into the load bank. It is equipped with a charge control button and \/ or control with touch panel.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-19\" style=\"--awb-content-alignment:left;\"><h3>Manual control with illuminated button<\/h3>\n<p>METAL DEPLOYE RESISTOR leaves the possibility of controlling the load bank using an illuminated ON \/ OFF button.<\/p>\n<p>A button controls a defined load, a simple addition gives the engaged power.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-19 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-20\" style=\"--awb-content-alignment:left;\"><h3>External control by dry contact<\/h3>\n<p>This command mode can be used alone or with all types of Supervision.<\/p>\n<p>Here it is the generator which comes to control the load directly on the load bank. Load and ventilation control is available on the terminal block: status information for the power contactors and the motor contactor.<\/p>\n<p>Also available on terminal block:<\/p>\n<ul>\n<li>Head circuit breaker status<\/li>\n<li>Ventilation contact feedback<\/li>\n<li>Remote emergency stop<\/li>\n<\/ul>\n<h3>External control via MODBUS<\/h3>\n<p>Modbus TCP \/ IP Communication is a language protocol between the generator set and the load bank PLC.<br \/>\nThe load bank will be controlled by an external control system via an exchange table.<br \/>\nThis command mode requires the Supervision command in \u201cPremium\u201d mode.<\/p>\n<h3>Automatic ballasting and deballasting included<\/h3>\n<p>The automatic ballasting \/ unloading option allows, via a current transformer, to regulate the load of the bank according to the value of the current consumed by the installation. This variation can be managed with respect to the current delivered by the generator set or with respect to the consumption of the network.<\/p>\n<p>The point is to <strong>maintain a minimum load on your generator set<\/strong> during operation to prevent premature wear.<\/p>\n<p>The use of automatic ballast \/ deballast mode is available via a supervision type control mode.<\/p>\n<p>The supply and installation of the current transformer is not included, a connection terminal block is provided for this purpose in the electrical compartment of the load bank.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-7 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-gris\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-20 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-21\" style=\"--awb-content-alignment:center;\"><h2>MASTER Supervision: simultaneous control of several banks<\/h2>\n<\/div><div class=\"fusion-text fusion-text-22\" style=\"--awb-content-alignment:left;\"><p>You have the possibility of controlling several load banks from a single control interface.<br \/>\nThis function is intended<strong> increase testing capacity<\/strong> by adding the nominal power of each connected load bank.<br \/>\nThe operation is identical to the single bank mode.<\/p>\n<\/div><div class=\"fusion-text fusion-text-23\" style=\"--awb-content-alignment:left;\"><p>It is possible to control several load banks simultaneously:<\/p>\n<ul>\n<li>via a computer (Windows environment)<\/li>\n<li>via a remote remote control<\/li>\n<\/ul>\n<p><strong>Features<\/strong><\/p>\n<ul>\n<li>Automatic recognition of load banks<\/li>\n<li>Manual or cycle control<\/li>\n<li>Display of network parameters and graphical visualizations<\/li>\n<li>Saving and exporting data<\/li>\n<\/ul>\n<p>Depending on your needs, 2 remote controls are available:<\/p>\n<ul>\n<li><strong>Multi-bank remote control<\/strong> : control of up to 4 load banks<\/li>\n<li><strong>RC48 Performance remote control<\/strong> : control of up to 48 banks, of different technologies and powers<\/li>\n<\/ul>\n<p>H3 \"BASIC\" or \"PREMIUM\": how to choose the right option according to your needs? H3<\/p>\n<p>It is possible to control a load bank remotely using a remote screen or a control case.<\/p>\n<p>Developed by<a href=\"https:\/\/www.mdresistor.com\/en\/who-we-are\/\"> our R&amp;D teams<\/a> , 2 systems - \"BASIC\" and \"PREMIUM\", which can be used via a remote remote control. That is to say, a control case connected to the load bank by a cable and which will allow remote control.<br \/>\nIt is an ergonomic facility especially when the<a href=\"https:\/\/www.mdresistor.com\/en\/load-banks\/\"> test bank<\/a> are placed for example in a warm room, in height or even outside.<\/p>\n<\/div>\n<div class=\"table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\">BASIC MODE<\/th>\n<th align=\"left\">PREMIUM MODE<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\">Manual command<\/td>\n<td align=\"left\">Automatic control<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td align=\"left\">Basic functions<\/td>\n<td align=\"left\">Advanced functions<br \/>\nCycle, ballast, data management<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td align=\"left\">\n<ul>\n<li>An emergency stop button<\/li>\n<li>A white voltage presence indicator<\/li>\n<li>A visualization of faults and states of the load bank<\/li>\n<li><strong>4.3-inch<\/strong> color touch screen control<\/li>\n<li>Manual power up \/ down from the touch screen (not configurable)<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\">\n<ul>\n<li>An emergency stop button<\/li>\n<li>A white voltage presence indicator<\/li>\n<li>A visualization of faults and states of the load bank<\/li>\n<li>Data recording and export in csv format<\/li>\n<li><strong>7-inch<\/strong> Color touch screen control<\/li>\n<li>Manual or configurable power up \/ down from the touch screen<\/li>\n<li>Display of activated power on touch screen<\/li>\n<li>Viewing Network Settings<\/li>\n<li>Display of instantaneous values and value curves<\/li>\n<li>Parameter setting of the power up and down cycles on touch screen (20 steps max)<\/li>\n<li>Storage of 20 cycles of 20 steps<\/li>\n<li>Possibility of requesting validation before moving to the next step<\/li>\n<li>Optional: Operation in ballast mode. Ballasting, automatic generator load deballasting<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-8 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling container-blanc\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1040px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-21 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:10px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-24\" style=\"--awb-content-alignment:center;\"><h2>Customization options for a tailor-made load bank<\/h2>\n<\/div><div class=\"fusion-text fusion-text-25\" style=\"--awb-content-alignment:left;\"><p>METAL DEPLOYE RESISTOR is at your disposal to define the specific options and equipment related to your needs:<\/p>\n<ul>\n<li><strong>Need a trailer<\/strong> : road transport trailer equipped with Timon. Weight under 750 kg, without license:<a href=\"https:\/\/www.mdresistor.com\/en\/portable-load-bank\/\"> see our road trailer for load bank<\/a><\/li>\n<li><strong>Any other customization of your load bank<\/strong> : personalized colors, with cable storage box, storage and transport protections ...:<a href=\"https:\/\/www.mdresistor.com\/en\/load-bank-customizations\/\"> see all our loadbank customization options<\/a><\/li>\n<li><strong>Need for mobility and transport<\/strong> : lifting ring, transport \/ handling castors, a skid frame (or base with fork passage)\u2026 See all the options of<a href=\"https:\/\/www.mdresistor.com\/en\/programmable-load-bank\/\"> moving a load bank<\/a><\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-4870","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Load bank : piloting and control - METAL DEPLOYE RESISTOR<\/title>\n<meta name=\"description\" content=\"Load bank control system. Manual \/ external. Charge cycle configuration. Ballasting \/ shedding. 80 years of expertise. Made in France\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Load bank : piloting and control - METAL DEPLOYE RESISTOR\" \/>\n<meta property=\"og:description\" content=\"Load bank control system. Manual \/ external. Charge cycle configuration. Ballasting \/ shedding. 80 years of expertise. Made in France\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/\" \/>\n<meta property=\"og:site_name\" content=\"MDResistor\" \/>\n<meta property=\"article:modified_time\" content=\"2022-02-02T01:21:54+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"53 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/supervision-and-steering\\\/\",\"url\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/supervision-and-steering\\\/\",\"name\":\"Load bank : piloting and control - METAL DEPLOYE RESISTOR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/#website\"},\"datePublished\":\"2020-12-04T17:04:02+00:00\",\"dateModified\":\"2022-02-02T01:21:54+00:00\",\"description\":\"Load bank control system. Manual \\\/ external. Charge cycle configuration. Ballasting \\\/ shedding. 80 years of expertise. Made in France\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/supervision-and-steering\\\/\"]}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/\",\"name\":\"MDResistor\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mdresistor.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Load bank : piloting and control - METAL DEPLOYE RESISTOR","description":"Load bank control system. Manual \/ external. Charge cycle configuration. Ballasting \/ shedding. 80 years of expertise. Made in France","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/","og_locale":"en_US","og_type":"article","og_title":"Load bank : piloting and control - METAL DEPLOYE RESISTOR","og_description":"Load bank control system. Manual \/ external. Charge cycle configuration. Ballasting \/ shedding. 80 years of expertise. Made in France","og_url":"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/","og_site_name":"MDResistor","article_modified_time":"2022-02-02T01:21:54+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"53 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/","url":"https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/","name":"Load bank : piloting and control - METAL DEPLOYE RESISTOR","isPartOf":{"@id":"https:\/\/www.mdresistor.com\/en\/#website"},"datePublished":"2020-12-04T17:04:02+00:00","dateModified":"2022-02-02T01:21:54+00:00","description":"Load bank control system. Manual \/ external. Charge cycle configuration. Ballasting \/ shedding. 80 years of expertise. Made in France","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mdresistor.com\/en\/supervision-and-steering\/"]}]},{"@type":"WebSite","@id":"https:\/\/www.mdresistor.com\/en\/#website","url":"https:\/\/www.mdresistor.com\/en\/","name":"MDResistor","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mdresistor.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/pages\/4870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/comments?post=4870"}],"version-history":[{"count":5,"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/pages\/4870\/revisions"}],"predecessor-version":[{"id":6840,"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/pages\/4870\/revisions\/6840"}],"wp:attachment":[{"href":"https:\/\/www.mdresistor.com\/en\/wp-json\/wp\/v2\/media?parent=4870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}